Question #4
Which tool is required to pull backbone cable of significant weight?
Correct answer: D
Explanation
A tugger provides the mechanical pulling force needed for heavy backbone cable; a pulling eye only attaches the rope, and pull string is for lightweight runs.
Question #9
You are terminating a category 3 cable. What is the maximum permissible amount of untwisting?
Correct answer: C
Explanation
Category 3 permits up to 75 mm (3 in) of untwisting at the termination; higher categories are far tighter, at 13 mm for Category 5e and above.